Kia Carens: Engine Control System / Heated Oxygen Sensor (HO2S) Specifications

Kia Carens RP (2013-2018) Service Manual / Engine Control / Fuel System / Engine Control System / Heated Oxygen Sensor (HO2S) Specifications

Specification
HO2S [Bank 1/Sensor 1]
Item
Specification
Heater Resistance (Ω)
2.4 ~ 4.0 [20°C(68°F)]

HO2S [Bank 1/Sensor 2]
A/F Ratio (λ)
Output Voltage(V)
RICH
0.6 ~ 1.0
LEAN
0 ~ 0.4

Item
Specification
Heater Resistance (Ω)
Approx. 9.0 [21°C(69.8°F)]

Heated Oxygen Sensor (HO2S) Description and operation
Description Heated Oxygen Sensor (HO2S) consists of zirconium and alumina and is installed both upstream and downstream of the Manifold Catalytic Converter. The sensor output vol ...

Heated Oxygen Sensor (HO2S) Troubleshooting
Signal Waveform ...

Other information:

Kia Carens RP (2013-2018) Owners Manual: Normal Maintenance Schedule - Except Europe


The following maintenance services must be performed to ensure good emission control and performance. Keep receipts for all vehicle emission services to protect your warranty. Where both mileage and time are shown, the frequency of service is deter mined by whichever occurs first. I : Inspect ...

Kia Carens RP (2013-2018) Owners Manual: Explanation of scheduled maintenance items


Engine oil and filter The engine oil and filter should be changed at the intervals specified in the maintenance schedule. If the car is being driven in severe conditions, more frequent oil and filter changes are required. Drive belts Inspect all drive belts for evidence of cuts, cracks, excessive ...