Item
|
Specification
|
Current voltage
|
13V
|
Working voltage
|
DC
10~15V
|
Operating force
|
3.0kg Max
|
Voltage drop
|
-0.4V
|
Working temperature
|
-30°C ~ 100°C
[-30°F ~ 212°F]
|
Description
Component location : Manual transaxle case
Operation principle : Back up lamp switch is pushed by the reverse lug sliding
when select arm, and switches the bac ...
Inspection
1.
Remove the air cleaner assembly.
(Refer to Engine Mechanical System - "Air Cleaner")
2.
Remove the batt ...
Other information:
Specifications
Item
Specifications
Working voltage
DC
12V
Operating force
9.8 ± 2.9N
(1.0 ± 0.3kg, 7.2 ± 0.7lb)
Voltage drop
-0.4V
W ...
Replacement
•
Put on gloves to protect your hands.
•
When ...